Specification
SPECIFCIATION
Part No. | WLL-200W-24-C |
Max Cooling power | 205W @ △T = 0℃ |
Voltage of Peltier cell | 24V |
Current of Peltier cell | Start 13.5 A / Working 11.5 A |
Hot side fan | 24V 0.6A,3000RPM,211CFM,56dBA |
Cold side fan | 24V,0.5A,3000RPM,126CFM,41dBA |
Operating Temperature | -10~70℃ |
Weight | 7.1 Kg |
Note | Cool only |
DIMENSION
PERFORMANCE CURVE
Note:
The performance curve give the example that when the intermal temperature is 50℃ and the environment temperature is 50℃, the cooler can transfer the 200W heat from inner side to the out side.
NOTES OF USE
Ø Please use the 24 V DC power with the ripple less than 10%.
Ø The cystal of Te2Bi3 is fragile. Intense crash is forbidden even the height is 10-20cm.
Ø No water resistance.Please use in the without water.
Ø When mounting, please keep 10 cm distance with other substance.
Ø please do not use it, when the temperature of the assembly or environment is higher than 70℃
NAME METHOD
Top